© 2021 United States Stove Company
5
CAUTION:
CONTACT YOUR LOCAL BUILDING OFFICIALS
TO OBTAIN A PERMIT AND INFORMATION
ON ANY ADDITIONAL INSTALLATION
RESTRICTIONS OR INSPECTION
REQUIREMENTS IN YOUR AREA.
US Stove highly recommends your stove be installed
by a qualied NFI (US) or WETT (Canada) technician.
To nd the nearest qualied installer, go to:
https://ncertied.org,
https://www.wettinc.ca/
INSTALLATION OPTIONS
Read this entire manual before you install and
use your pellet stove. Failure to follow instructions
may result in property damage, bodily injury, or
even death! Before installing your heater, you must
perform an initial burn in an OUTSIDE environment.
Follow the Start-Up Procedure in the “Operation”
section of this manual. See specic installation
details for clearances and other installation
requirements. Your pellet stove may be installed
to code in either a conventional or mobile home
(see Standard Mobile Home Requirements). It is
recommended that only a authorized technician
install your heater, preferably a National Fireplace
Institute (NFI) certied specialist. This heater must
be installed on an exterior wall to allow exhaust
venting to meet the minimum required clearances.
Once the desired location is selected, and before
cutting a hole, check the outside of the structure
for anything obstructing clearances to the exhaust
vent. Also clear away leaves, shrubs/bushes, or trees
that may be around the exhaust outlet.
CAUTION:
BEFORE INSTALLING YOUR HEATER, YOU
MUST PERFORM AN INITIAL BURN IN AN
OUTSIDE ENVIRONMENT. FOLLOW THE
START-UP PROCEDURE IN THE OPERATION
SECTION OF THIS MANUAL.
IMPROPER INSTALLATION
The manufacturer will not be held responsible
for damage caused by the malfunction of a stove
due to improper venting or installation. Consult a
professional installer if you have any questions.
FLOOR PROTECTION
This heater must have a non-combustible oor
protector (ember protection) installed beneath it if
the oor is of combustible material. If a oor pad
is used, it should be UL listed or equal. The oor
protector should be large enough to extend under
the stove and beyond each side as indicated. A
Floor Protector of 1/4” thick is recommended for
this installation
A
Floor Protector
A
B
A Sides
USA 2” (51 mm)
CAN 8” (200 mm)
B Front
USA 6” (152 mm)
CAN 18” (450 mm)