For WF150K.

PDF File Manual, 27 pages, Read Online | Download pdf file

WF150K photo
Loading ...
Loading ...
Loading ...
Page 11
www.123filter.com | (678) 261-7611 | support@123filter.com
If the water inlet pressure is higher than 125 psi, a pressure reducing valve must be installed at the
water inlet pipe of the water purifier. If the water inlet pressure is lower than 20 psi, a booster pump
must be installed at the water inlet pipe of the water purifier to ensure the working pressure meets
technical requirements. In addition, a pressure reducing valve or booster pump should be installed
between the water inlet pipe and the water supply pipe of this product.
During installation, pay attention to the direction of water flow, connect the inlet and outlet pipes
according to the inlet and outlet signs, and ensure there is no water leakage after installation.
Verify that the distance between the water outlet of the product and the water inlet of the water
heater is greater than 3 meters. If the connection distance of 3 meters cannot be guaranteed, it is
recommended to install a check valve between the water purifier and the hot water heater to prevent
hot water from causing severe damage to the purifier’s internal treatment system.
The installation and commissioning of all machines must be conducted only by a professional
technician.