Step 4: Connect signal and power cables
The outdoor units terminal block is protected by
an electrical wiring cover on the side of the unit.
A comprehensive wiring diagram is printed on the
inside of the wiring cover.
WARNING
BEFOREPERFORMINGANYELECTRICALORWIRING
WORK, TURN OFF THE MAIN POWER TO THE
SYSTEM.
1. Preparethecableforconnection:
USETHERIGHTCABLE
IndoorPowerCable(ifapplicable):H05VV-For
H05V2V2-F
OutdoorPowerCable:H07RN-F
SignalCable:H07RN-F
CHOOSETHERIGHTCABLESIZE
Thesizeofthepowersupplycable,signalcable,
fuse, and switch needed is determined by the
maximum current of the unit. The maximum
current is indicated on the nameplate located on
the side panel of the unit. Refer to the nameplate
to choose the right cable, fuse, or switch.
a. Using wire strippers, strip the rubber jacket
from both ends of the cable to reveal about
1.57in of the wires inside.
b. Strip the insulation from the ends of the wires.
c. Using a wire crimper, crimp u-lugs on the ends
of the wires.
PAY ATTENTION TO LIVE WIRE
While crimping wires, make sure you clearly
distinguish the Live (“L) Wire from other wires.
WARNING
ALLWIRINGWORKMUSTBEPERFORMEDSTRICTLY
INACCORDANCEWITHTHEWIRINGDIAGRAM
LOCATED INSIDE OF WIRE COVER OF THE
OUTDOOR UNIT.
2. Unscrew the electrical wiring cover and
remove it.
3. Unscrew the cable clamp below the terminal
block and place it to the side.
4. Connect the wire according to the wiring
diagram,and�rmlyscrewtheu-lugofeach
wire to its corresponding terminal.
5. After checking to make sure every connection
is secure, loop the wires around to prevent
rainwaterfromflowingintotheterminal.
6. Using the cable clamp, fasten the cable to the
unit. Screw the cable clamp down tightly.
7. Insulate unused wires with PVC electrical tape.
Arrange them so that they do not touch any
electrical or metal parts.
8. Replace the wire cover on the side of the unit,
and screw it in place.
Cover
Screw
In North America
1. Remove the wire cover from the unit by
loosening the 3 screws.
2. Remove the caps on the conduit panel.
3. Temporarily mount the conduit tubes (not
included) on the conduit panel.
4. Properly connect both the power supply
and low voltage lines to the corresponding
terminals on the terminal block.
5. Groundtheunitinaccordancewithlocal
codes.
6. Besuretosizeeachwireallowingseveral
inches longer than the required length for
wiring.
7. Use lock nuts to secure the conduit tubes.
G
Wire Cover
Ov
e
r 1
.5
7
in.
(
40
m
m
)
Terminal block
Conduit panel
Connecting cable
Power supply cord
Please select the appropriate through-hole according
to the diameter of the wire.
Installation