Unied Access Point Administrator’s Guide
Unied Access Point Administrator’s Guide
Page 48
October 2017
Section 4 - Managing the Access Point
A valid rule must contain all of the following parameters:
•) Days of the Week.
•) Start Time (hour and minutes).
•) End Time (hour and minutes).
Only valid rules are added to the prole. Up to 16 rules are grouped together to form a scheduling prole. Any two
periodic rules time entries belonging to the same prole must not overlap. The time granularity for the schedules is
one minute. The DWL-x600AP supports up to 16 proles.
Figure 21 - Scheduler Conguration
Field Description
Global Scheduler
Mode
A global switch to enable or disable the scheduler feature. The default is Disable.
Scheduler Operational Status
Status The operational status of the Scheduler. The range is Up or Down. The default is Down.
Reason Provides additional information about the status. The reason can be one or more of the
following:
•) IsActive – Operational status is up.
•) CongDown – Operational status is down because global conguration is disabled.
•) TimeNotSet – Operational status is down because the AP time has not been set,
either manually or by specifying an NTP server to use.
•) ManagedMode– Operational status is down because the AP is in managed mode.
Scheduler Prole The Scheduler prole denes the list of proles names that can be associated to the VAP or
Radio conguration. Rules are associated with a named scheduler prole. You can dene up
to 16 scheduler prole names. By default, no proles are created.
The prole name can be up to 32 alphanumeric characters. Click Add to add the prole
name.
Rule Conguration Each scheduler prole may have up to 16 periodic rules. The list of parameters for each
periodic rule are described below.
Select Prole Select the prole name from the menu.
Set Schedule The day of the week. Range is: Daily, Weekday (Monday to Friday), Weekend (Saturday
and Sunday), Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday. The
default is Daily.
Start Time The time when the radio or VAP will be operationally enabled. The time is in HH:MM 24-hour
format. The range is <00-23>:<00-59>. The default is 00:00.
End Time The time when the radio or VAP will be operationally disabled. The time is in HH:MM 24-
hour format. The range is <00-23>:<00-59>. The default is 00:00.
Table 22 - Scheduler Conguration
After you select a prole from the Select Prole eld, the rules that have been added to the selected prole appear
in the table below the Rule Conguration area. When you add a new rule to a prole, it appears in the table. Use the