COUNTER PREPARATION
Consult Table 1 for enclosure cut-out dimensions. If the
counter or any supporting construction is combustible, the
COMBUSTIBLE ENCLOSURE CUT-OUT section must be
followed before beginning the installation.
This sideburner must be supported by the stainless-steel
hanger extending from the upper portion of the frame. The
hanger rests on the left, right, and back of the countertop.
The control panel is designed to sit fl ush against the enclosure
front wall (see Fig. 15-2). If the enclosure countertop extends
beyond the front wall, creating a countertop overhang (see
Fig. 15-1), it must be cut fl ush with the front wall for the width
of the control panel or a gap will be created exposing the
forward portions of the left and right side fi re walls of the unit.
See the MODEL SPECIFICATIONS section.
Note: It is not necessary to remove the control panel or
knobs to install this unit.
CONNECT THE GAS SUPPLY
For propane cylinders:
For connecting a propane unit to a portable propane tank,
read the safety warnings and follow the instructions in the
section SAFE USE AND MAINTENANCE OF PROPANE
GAS CYLINDERS.
Note: When a propane cylinder is installed inside of the
enclosure, the guidelines found in the ENCLOSURE
REQUIREMENTS section MUST be followed.
For household propane or natural gas units:
CAUTION: Use only C.S.A. listed stainless-steel flex
connectors within the enclosure.
WARNING
A rubber or plastic connector will rupture or leak,
resulting in an explosion or serious injury if used inside
the appliance enclosure.
1. Locate the attached fl ex connector (found underneath
the unit) and route it to the gas-supply stub.
2. Turn OFF the gas supply at the source.
3. A shut-off valve is required within 6 feet of the unit.
If shut-off valve is connected to end of gas supply
stub:
Connect the fl ex connector to the shut-off valve (see
Fig. 15-3). Tighten securely.
If shut-off valve is installed in-line:
Install the supplied fl are adapter to the gas supply
using a pipe joint compound resistant to all gasses
(see Fig. 15-3). Tighten securely.
Connect the fl ex connector to the fl are adapter (see
Fig. 15-3). Tighten securely.
INSTALLATION
INSTALLATION
Fig. 15-3 Connecting to a gas line
Gas supply
Flare adaptor
(use on gas
supply stub only
if shut-off valve
installed in-line)
Flex connector
(coming from unit)
Shut-off valve
(required, not
included, must be
installed within 6 feet
of unit)
(Countertop)
GAP CREATED
Proposed cut-out
in overhang
Control panel
stops here
INCORRECT
Fig. 15-1 Countertop overhang - incorrect cutout
IDEAL
Flush-mounted
control panel
Overhang
Fig. 15-2 Countertop overhang - correct cutout
CORRECT
(Countertop)
Fig. 15-4 Household propane & natural gas diagram
OFF
To gas system
Gas inlet pipe
Flex
connector
Hanger
Countertop
Cut-out
Pipe adapter fi tting
Shut-off valve (shown
in-line) must be within
6 feet of the unit.