GX36 MAXIMUM REAR VENT CLEARANCES (EXAMPLE 1)
REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 44" (1118mm). For temperature
requirements, the enclosure space around and above the appliance must be left
unobstructed.
24"
[610mm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBL
FINISHING IS USED
SUCH AS BRICK
AND STONE.
10"
[254mm]
44"
1
118mm]
10"-20"
[254mm-508mm]
VENT RUN
14 1/2"
[368mm]
NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the
combustible wall penetration.