Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/13566187-b36ntr/bg17.png)
23
W415-1401 / C / 03.18.15
EN
3.11 REAR EXIT
!
WARNING
FAILURE TO INSTALL THE CAP WILL CAUSE THE APPLIANCE TO FUNCTION IMPROPERLY AND
CAN CAUSE INJURY OR PROPERTY DAMAGE.
A. Remove the safety screen and glass front, refer to "
SAFETY SCREEN & DOOR REMOVAL / INSTALLATION"
section.
B. Remove the contents from the fi rebox and set aside, you
will need the exhaust fl ue collar from the top of the log
carton.
C. To ease assembly, remove the four hex head screws
securing the defl ector from inside the top front of the fi rebox, refer to Figure 1.
D. Place the gasket (provided) over the 4" (102mm) fl ue collar assembly and
bend along perforation.
E. From inside the fi rebox, insert the 4" (102mm) fl ue collar through the back
of the fi rebox. Secure the fl ue collar assembly and gasket using the four
hex head 3/8" thread cutting screws, refer to Figure 2. NOTE: Do not
overtighten. The gasket needs only to be snug against the fi rebox.
F. Re-attach the defl ector using the four screws and install the log set, glass
door and safety screen.
Fig. 2
DEFLECTOR
90°
V
1
V
2
H
1
H
2
90°
90°
H
3
45°
18.2_3A
Example:
V
1
= 1.5 FT (0.5m)
V
2
= 5 FT (1.5m)
V
T
= V
1
+ V
2
= 1.5FT (0.5m)+ 5FT (1.5m) = 6.5 FT (2m)
H
1
= 1 FT (0.3m)
H
2
= 1 FT (0.3m)
H
3
= 10.75 FT (3.3m)
H
R
= H
1
+ H
2
+ H
3
= 1FT (0.3m) + 1FT (0.3m) + 10.75FT (3.3m) = 12.75FT (3.9m)
H
O
= .03 (four 90° elbows + one 45° elbow - 90°)
= .03 (360° + 45° - 90°) = 6.75 FT (2.1m)
H
T
= H
R
+ H
O
= 12.75FT (3.9m) + 6.75FT (2.1m) = 19.5 FT (5.9m)
H
T
+ V
T
= 19.5FT (5.9m) + 6.5FT (2m) = 26 FT (7.9m)
Formula 1:
H
T
< 3 V
T
3 V
T
= 3FT (0.9m) x 6.5FT (2m) = 19.5FT (5.9m)
19.5FT (5.9m) = 19.5FT (5.9m)
Formula 2:
H
T
+ V
T
< 40 FT (12.2m)
26 FT (7.9m) < 40 FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
Fig. 1
NOTE: A #42 orifi ce was supplied with your appliance. In installations with a vertical rise greater than
8" (203mm) in the vent confi guration, the #42 orifi ce must be used to increase the fl ame size.