* See "VENTING" section.
REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 41" (1041mm). For temperature
requirements, the enclosure space around and above the appliance must be left
unobstructed.
24"
[610mm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
7"
[178mm]
41"
[1041mm]
1"-10"
[25mm-254mm]
VENT RUN
54"
[1376mm]
CEILING
(MIN)
B36 MINIMUM REAR VENT CLEARANCES
For rear vent termination not exceeding 10" (254mm) of horizontal vent run.
NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the
combustible wall penetration.