Loading ...
Loading ...
Loading ...
27
Gate Operator Setup Examples
The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site
requirements, including all necessary entrapment protection devices.
COMMERCIAL/GENERAL ACCESS: A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access
trumps security concerns
COMMERCIAL: Business site where security (gate closed) is important
INDUSTRIAL: Large business site where security is required
SETTING
COMMERCIAL/GENERAL ACCESS
COMMERCIAL INDUSTRIAL
Quick Close switch setting
Normally set to OFF. Normal gate close
(timer or control).
Normally set to OFF. Normal gate close
(timer or control).
Set to ON, so that gate closes immediately
after vehicle passes CLOSE EYES/Interrupt
loop.
AC Fail Open switch setting
Normally set to BATT. For local jurisdiction
requirement, set to OPEN so that the gate will
open approximately 15 seconds after AC
power fail.
Normally set to BATT. Run on battery if AC
power fails.
Normally set to BATT. Run on battery if AC
power fails.
Low Battery switch setting
Normally set to OPEN. If powered from
battery and battery is low, gate automatically
opens and stays open.
Normally set to CLOSE. If powered from
battery and battery is low, gate stays closed.
Normally set to CLOSE. If powered from
battery and battery is low, gate stays closed.
Anti-Tail switch setting
Normally set to OFF. CLOSE EYES/Interrupt
loop reverses a closing gate.
Set to ON. In attempt to prevent vehicle tail-
gating, CLOSE EYES/ Interrupt loop pauses a
closing gate.
Set to ON. In attempt to prevent vehicle tail-
gating, CLOSE EYES/ Interrupt loop pauses a
closing gate.
Bipart Delay switch setting
For DUAL-GATE site, set to ON for gate that
delays upon opening.
For DUAL-GATE site, set to ON for gate that
delays upon opening.
For DUAL-GATE site, set to ON for gate that
delays upon opening.
Aux Relay Out Open Limit
Switch
Use with SAMS (Sequence Access
Management System).
1. Use with SAMS (Sequence Access
Management System).
2. Connect “Gate Open” indicator (e.g.
light).
1. Use with SAMS (Sequence Access
Management System).
2. Connect “Gate Open” indicator (e.g.
light).
Aux Relay Out Close Limit
Switch
Typically not required. Connect “Gate Close/Secure” indicator (e.g.
light).
Connect “Gate Close/Secure” indicator (e.g.
light).
Aux Relay Out Gate
Motion
Attach alert signal (audible or visual alert
system).
Attach alert signal (audible or visual alert
system).
Attach alert signal (audible or visual alert
system).
Aux Relay Out Pre-Motion
Delay
Attach alert signal (audible or visual alert
system).
Attach alert signal (audible or visual alert
system).
Attach alert signal (audible or visual alert
system).
Aux Relay Out Power
Attach visual alert to know when system is
charging batteries (i.e. not running on
batteries).
Attach visual alert to know when system is
charging batteries (i.e. not running on
batteries).
Attach visual alert to know when system is
charging batteries (i.e. not running on
batteries).
Aux Relay Out Tamper
(Slide Gates Only)
Attach alert signal (audible or visual alert
system) to indicate if gate is manually
tampered with by being pushed off of close
limit.
Attach alert signal (audible or visual alert
system) to indicate if gate is manually
tampered with by being pushed off of close
limit.
Attach alert signal (audible or visual alert
system) to indicate if gate is manually
tampered with by being pushed off of close
limit.
Cycle Quantity Feedback
Use during servicing only to determine
operator cycles.
Use during servicing only to determine
operator cycles.
Use during servicing only to determine
operator cycles.
Fire Dept Open Input
Connect emergency access system (Knox box
switch, SOS system, etc.).
Typically not required. Typically not required.
OPERATION
Loading ...
Loading ...
Loading ...