Blaze BLZ3LBMNG Blaze BLZ3LBMNG 25 Inch Outdoor Built-In Gas Grill

USE & CARE GUIDE - Page 16

For BLZ3LBMNG. Also, The document are for others Blaze models: BLZ-3LBM(NG/LP), BLZ-4LBM(NG/LP)

PDF File Manual, 39 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Page 16
the appliance and release pressure in the hose and manifold by pushing in and turning any of the control
valves one quarter turn counter-clockwise.
On LP systems, remove the cylinder from the appliance.
Call an authorized gas appliance service technician or an LP gas dealer.
Do not use the appliance until the leak is corrected.
The below diagram is intended to show what a leaking connection would look like. These two locations are not
the only points to check nor the only potential areas for a gas leak to be present.
Leak Testing
All gas piping and connections must be tested for leaks after installation or service along with before
each use. This includes all valves, pipe connections, joints, lines and every point from the gas source
to the burners.
All leaks must be corrected immediately. Remember-before exchanging an empty bottle for a new one; make sure all
control valves are in the “off” position. This can create a low flow of gas through the grill. This would require the tank to be
disconnected from the regulator, and then reconnected to reset the regulator.
Open the valve (shut-off or ‘ON’ LP tank). Test for leaks by applying liquid soap solution to all joints. Bubbles forming
indicate gas leak.
The following diagram is for informational purposes only. These locations are not the only points to check nor
the only potential areas for a gas leak to be present. Ensure the leak test includes all valves, pipe
connections, joints, lines and every point from the gas source to the burners.