to operate.
Never connect the appliance to an unregulated gas supply line. Appliances operated without a regulator are unsafe
and will not be serviced until installed properly and safely. Unsafe operation without a gas regulator will void the
warranty of the appliance.
Appliances operated with NG (natural gas) gas must be installed with the NG regulator supplied with the unit and
set to 4.0" water column pressure.
Appliances operated with LP (liquid propane) gas must be installed with an LP regulator set to 11" water column
pressure.
Please contact your dealer and use a licensed contractor or installer to convert your appliance to the different
gas type.
CHECK TO ENSURE THAT THE GAS SUPPLY HOSE DOES NOT COME IN CONTACT WITH ANY HOT SURFACE,
SHARP OR ROUGH EDGES OF THE GRILL OR OUTDOOR KITCHEN CONSTRUCTION. DO NOT KINK THE GAS LINE
WHEN INSTALLING.
The self-contained LP system appliance is design certified to be used with a standard 20 lb., 12 1/4" diameter; 18" high
cylinder with right-handed connection threads and this is the maximum size LP tank to be used. The cylinder must be marked
in accordance with the latest U.S. Department of Transportation specifications for LP gas cylinders. (DOT. CFR49 or National
Standards of Canada CAN/CSA-B359 Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods) a Propane
Tank with an ODP) Overfill Prevention Device) must be used at all times.
IMPORTANT: Never connect the appliance to an unregulated gas supply.
If there are local codes that apply to outdoor grills, you will have to confirm them with the local authority.
Installation must conform with local codes or in the absence of local codes, to the National Fuel Gas Code, ANSI
Z223.1/NFPA 54 and Natural Gas Installation Code, CSA B149.1. All Natural Gas installations must conform to local
codes or in the absence of local codes the national fuel gas code, ANSIZ2223.1a-1998.
If there are local codes that apply to outdoor burners, you will have to conform to them. Installation must conform with
local codes or, in the absence of local codes, with Propane Installation Code, CSA B149.1, or Propane Storage and
Handling Code, B149.2 as applicable.
Installation in Canada must be in accordance with the standard CAN/CGA- B149.2.
A licensed contractor or local gas company representative must perform all gas connections.
Ensure that the service supplying the appliance is fitted with a shut off valve conveniently positioned near the appliance and
giving ease of access.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure
testing of that system.