4. Rotate blade and check the same
marked point 1 of the saw blade at the
front of the table (Fig. 20).
5. If the front and back measurements,
shown in Figure 22, are not identical,
loosen the four alignment bolts 2, lo-
cated on the underside of the table at
the front and rear of the saw with hex
wrench supplied with your saw (Fig. 21
and 22). Carefully move the saw blade
until the blade is parallel to the miter
gauge slot, and securely tighten all four
bolts.
MITER GAUGE ADJUSTMENT
To check your miter gauge accuracy, move the
miter gauge in line with blade and use a com-
bination square to make sure the miter gauge
body is 90 degress to the blade (Fig. 23).
To adjust the miter gauge for 90 degrees:
1. Loosen lock nut 3, adjustment screw 4,
and lock knob 5.
2. Flip stop plate 6 down.
3. Rotate miter gauge body until it is 90 de-
grees to the blade.
4. Tighten lock knob 5.
5. Flip stop plate 6 up and tighten adjust-
ment screw 4 until it contacts stop plate
6.
6. Tighten lock nut 8.
7. If pointer 7 is not pointing to 90 de-
grees, loosen set screw 8 on side of
miter gauge bar and rotate pointer 7 to
90 degrees mark. Tighten set screw 8.
8. To adjust the miter gauge for 45 degress
left and right, repeat steps 1-6, but use
45 degree stops.
21
2
UNDER REAR OF TABLE
Adjustments
4
83
6
5
7
Fig. 22
Fig. 23