Ashley AGVF340N 1,200 Sq. Ft. Single-Burner Vent Free Natural Gas Stove

User Manual - Page 18

For AGVF340N.

PDF File Manual, 28 pages, Download pdf file

Loading ...
Loading ...
Loading ...
18
© 2020 United States Stove Company
for your replace from formal wall treatments with
marble and mantels, to rustic wood paneling, stone
or brick. Noncombustible materials used in this
installation such as slate, tile, marble, etc. must be
at least 1/2” thick. IT IS IMPORTANT THAT BLACK
FACE OF FIREPLACE NOT BE COVERED WITH ANY
TYPE OF COMBUSTIBLE MATERIAL. Check to see
whether man-made brick and stone are made of
non-combustible materials before using them on
the face of the replace. Some of these products
contain combustible materials. Combustible wall
coverings such as paneling or wall-board may
not overlap the black face of the replace. Space
between wall covering and replace should be
sealed with a heat resistant material such as
glowing wool insulation or mortar. NOTE: An “L
shaped steel lintel must be installed across the top
of the rebox opening where facing materials such
as brick or stone is used on the face of the rebox. It
acts as a support/restop. It should be attached to
the face of the replace with screws and sealed to
the replace with a heat-resistant sealer.
CLEARANCES (ZC)
To ensure a safe installation, the dimensions of the
following gures must be carefully observed.
20” MIN. CLEARANCE TO
MANTEL OR SUPPORTS
7” MIN.
CLEARANCE
TO SIDE WALL
SIDE WALL
CEILING
24” MIN.
FREESTANDING INSTALLATION
1. Determine the exact position of your gas heater.
NOTE: Due to high temperatures, this heater should
be located out of trafc areas and away from
furniture and draperies.
NOTE: For safe installation, the minimum clearances
must be met as shown.
NOTE:
DIMENSIONSSHOWNARE
MINIMUMCLEARANCETO
COMBUSTIBLEWALL.
STOVE
7”
1-1/2
1-1/2”
24”
1-1/2”
1-1/2”
Attention: Maintain clearances listed above for any
required servicing and for proper operation of this
appliance
CAUTION:
THE INSTALLATION MUST CONFORM WITH
LOCAL CODES OR IN ABSENCE OF LOCAL
CODES, WITH NATIONAL FUEL GAS CODE,
ANSI Z223.1/NFPA54.
NOTE: See the “Gas Connection” section of this
manual for Gas Connection and Pressure Check.
1. Make sure you have the right valve for your
type of gas. Check the label on side of the valve.
Position logs as shown in the “Log Placement”
section of this manual. Position screen before
leaving the heater unattended.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
WARNING:
YOUNG CHILDREN SHOULD BE CAREFULLY
SUPERVISED WHEN THEY ARE IN THE SAME
ROOM WITH THE APPLIANCE. CHILDREN AND
ADULTS SHOULD BE ALERTED TO HAZARDS OF
HIGH SURFACE TEMPERATURE AND SHOULD
STAY AWAY TO AVOID BURNS OR CLOTHING
IGNITION.
INSTALLATION
Loading ...
Loading ...
Loading ...