Falcon NEX110SODFSS-CH Nexus Steam 110cm Freestanding Dual Fuel Oven/Stove SS

User Manual - Page 40

For NEX110SODFSS-CH.

PDF File Manual, 58 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
INSTALLATION
Check the appliance is gas sound when you have nished.
37
ArtNo.110-0023 - 110 - cooker clearances (AUS)
Hob
Trivet
Horizontal combustible surface
B
C
D
E
A
*
or
130 mm min
Positioning the Cooker
The diagram (Fig. 9.1) shows the minimum recommended
distance from the cooker to nearby surfaces as given in
AS/NZS5601.
Where the appliance is installed next to cabinetry, the
cabinet material must be capable of withstanding 70°C. If
this appliance is installed near vinyl wrapped surfaces, use an
installation kit available from the vinyl-wrap supplier. Falcon
cannot accept any responsibility for damage caused due to
installation into cabinets with low temperature tolerances.
*Any splashback must be tted in accordance with the
manufacturers instructions. Allowance should be made for
the additional height of the ue trim, which is tted to the
cooker hob.
1. Overhead – Measurement A
The minimum height of any surface above the cooker is
650 mm above the hotplate.
Cookerhoods and exhaust fans shall be installed in
accordance with the manufacturers instructions. However, in
no case shall the clearance between the highest part of the
hob of the cooking appliance and a cookerhood be less than
650 mm or, for an overhead exhaust fan, 750 mm.
2. Side Clearances – Measurements B & C
Where B, measured from the periphery of the nearest burner
to any vertical combustible surface is less than 200 mm, the
surface shall be protected by one of the following methods:
a. Fixing ceramic tiles with a minimum thickness of
5 mm to the surface.
b. Fixing toughened glass with a minimum thickness
of 5 mm to the surface, provided the glass is
approved by the manufacturer to be suitable for the
application.
c. Attaching re resistant material to the surface and
covering with sheet metal with a minimum thickness
of 0.4 mm.
Protection should be to a height C of not less than 150 mm
above the hob for the full dimension (width or depth) of the
cooking surface area.
3. Side Clearances – Measurement D & E
Where D, the distance from the periphery of the nearest
burner to a horizontal combustible surface is less than
200 mm, then E shall be 10 mm or more, or the horizontal
surface shall be above the trivet.
If the horizontal surface is above the trivet, then any vertical
combustible surface needs to be protected in accordance
with B above.
If the cooker is near a corner of the kitchen, a clearance of
130 mm is required to allow the oven doors to open (Fig. 9.2)
The actual opening of the doors is slightly less, but this allows
for some protection of your hand as you open the door.
We recommend a gap of 1110 mm between units to allow
for moving the cooker. Do not box the cooker in it must still
Fig. 9.1
Fig. 9.2
Loading ...
Loading ...
Loading ...