INSTALLATION
pipe may be attached for further termination through a
chimney. Clearance to combustibles must be considered
if this installation is chosen. A distance of 3 inches must
be maintained from the exhaust vent to any combustible
material.
INSTALLATION INTO A MASONRY
FIREPLACE
(4” Pell Vent “PL” Piping) that extends the full height of
the chimney and meets type HT requirements. The liner
must be securely attached to the insert and the chimney
top. The chimney must be sealed either at the top or at
the damper area with a non-combustible plate to prevent
room air passage to chimney cavity. Outside combustion
air may be drawn through the chimney top or through an
existing ash cleanout.
4” VENT IS MANDATORY FOR
INSERT INSTALLATIONS.
When installing into a masonry fireplace, DO NOT remove
any bricks or masonry, with the following exception:
masonry or steel, including the damper plate, may be
removed from the smoke shelf and adjacent damper
frame, if necessary, to accommodate a chimney liner. Do
this only if their removal will not weaken the structure
of the fireplace or the chimney, and will not reduce
protection for combustibles to less than that required
by national building codes. Installation must include a
chimney liner.
INSTALLATION INTO A FACTORYBUILT
(METAL) FIREPLACE
When installing into a zero clearance fireplace, The
firebox must accept the insert without modification other
than removing bolted or screwed together pieces such as
smoke shelf/deflectors, ash lips, screen or door tracks,
and damper assemblies. These items must be re-installed
if the insert is removed and not replaced. The removal of
any part must not alter the integrity of the listed fireplace
in any way. The factory built fireplace must be listed
per UL 127. Installation must include a chimney liner
(4” Pell Vent “PL” Piping) that extends the full height of
the chimney and meets type HT requirements. The liner
must be securely attached to the insert and the chimney
top. The chimney must be sealed either at the top or at
the damper area with a non-combustible plate to prevent
room air passage to chimney cavity. For raised hearth
installations, adjust the leveling bolts under the front of
the unit.
The metal sides, frame members, or other structural components of
the factory-built replace may not be removed or altered.
The masonry lining
may not be removed.
The Damper and
Internal Baes
may be removed
Flexible Stainless
Steel Pipe
Adjust Leveling Bolts
for raised replaces
NOTE: The Log Shelf, Screen,
and Doors (if present) must
be removed.
4” VENT IS MANDATORY FOR
INSERT INSTALLATIONS.