Napoleon GDS60-1NNSB Knightsbridge

User Manual - Page 15

For GDS60-1NNSB.

PDF File Manual, 116 pages, Read Online | Download pdf file

GDS60-1NNSB photo
Loading ...
Loading ...
Loading ...
EN
W415-2349 / A / 10.31.19
15
direct venting - model GDS60-1
2.5 defi nitions
2.6 elbow vent length values
For the following symbols used in the venting calculations and
examples are:
> - greater than
> - equal to or greater than
< - less than
< - equal to or less than
H
T
- total of both horizontal vent lengths (Hr) and offsets (Ho) in feet
H
R
- combined horizontal vent lengths in feet
H
O
- offset factor: .03 (total degrees of offset - 90°*) in feet
H
O
- offset factor: .03 (total degrees of offset - 135°*) in feet
V
T
- combined vertical vent lengths in feet
Feet Inches Millimeters
0.03 0.5 12.7
15° 0.45 6.0 152.4
30° 0.9 11.0 279.4
45° 1.35 16.0 406.4
90°* 2.7 32.0 812.8
* The fi rst 90° offset has a zero value and is shown in the formula as - 90°
* The fi rst 45° and° offset have a zero value and is shown in the formula as -45° and -90° respectively
or -135° when combined (for 45° exit only).