CONNECTING:'I_POWERSUPPLY:OUTLETi....
tf power:cord is worn or Cut, or damaged:in :anyway, have it
:replaced immediately.
WARNING: IF NOT PROPERLY GROUNDED THIS POWER
TOOLCANCAUSEANELECTRICALSHOCKPARTICULARLY
WHEN USED !N DAMP LOCATIONS CLOSE TO PLUMBING.
IF AN ELECTRICAL SHOCK OCCURS THERE iS THE
POTENTIAL OF A SECONDARY HAZARD SUCH AS YOUR
HANDS CONTACTING THE SAW BLADE.
Ifyou are notsure thatyour ouUet, aspicturedbelow, isproperly
grounded, have it checked by a qualified electrician.
Your unit is for use on 110-120 volts, and has a plug that looks
like illustration below.
This power tool is equipped with a 3-conductor cord and
grounding type plugwhich has a grounding prong, approved
by Underwriters' Laboratories and the Canadian Standards
Association: Th'e ground conductor has a green jacket and is
attached tothe toolhousing at one end and tothe ground prong
inthe attachment plug at the other end.
This plug requires amating 3-conductor grounded type outlet
as shown,
WARNING: DO NOT PERMIT FINGERS TO TOUCH THE
TERMINALS OF PLUGS WHEN INSTALLING OR REMOVING
THE PLUG TO OR FROM THE OUTLET,
PROPER_
GROUNDED
OUTLET
3-PRONG PLUG
GROUNDING PRONG
PRONG INANY MANNER. Use an adapter as shown below
andalways connect the grounding lug to known ground,
it iSrecommended that you have aqualified electrician replace
the TWO prongoutlet with a properly grounded THREE prong
outlet:
ADAPTER
3-PRONG
PLUG
GROUNDING LUG
MAKE SURETHIStS
CONNECTED TOA
KNOWN GROUND
2-PRONG
RECE PTACLE
An adapter as illustrated is available for connecting plugs to
2-prong receptacles.
WARN|NG: THE GREEN GROUNDING LUG EXTENDING
FROM THE ADAPTER MUST BE CONNECTED TO A
PERMANENT GROUND SUCH AS TO A PROPERLY
GROUNDED OUTLET BOX. NOT ALL OUTLET BOXES ARE
PROPERLY GROUNDED.
If you are not sure that your outlet box is properly grounded,
have it checked by a qualified electrician.
NOTE: The adapter illustrated isfor use only if you already have
a properly grounded 2-prong receptacle. Adapter is not allowed
in Canada by the Canadian Electrical Code.
The use of any extension cord will cause some loss of power,
Useonly 3 wire extension cords which have 3-prong grounding
type plugs and 3-pole receptacles which accept the tools plug.
Extension Cord Length Wire Size A.W.G.
Up to 100 Ft. 16
100-200 Ft: " 14
200-400 Ft. 10
contents
Warranty Information ...................... 2
General Safety Instructions for Power Tools,,. 2
Additional Safety Instruction for Scroll Saws., 3
Motor Specs and Electrical Information ...... 4
Unpacking & Checking Contents ............ 5
Assembly ............... ................ 6
Setting the Table for Horizontal or Bevel Cutting 6
Aligning the Bevel Indicator .................. 7
-:Removing and Installing Blades ........ .. ,. 9
Mounting the! Scroll Saw....:. ....... , , ...... 1 1
Operation ................... ............ 14
Making interior Cuts ....................... 14
Mounting an Auxiiliary Surface for the
Work Table ............................. 15
Maintenance ............................. 16
Glossary of Terms for Woodworking ......... 17
Wiring Diagram ........................... 17
Recommended Accessories ................ 17
Trouble Shooting ......................... 17
Repair Parts ............................. 18
Service information ....................... 20