31-2001053 Rev. 0 27
Installation
A
NEW CONSTRUCTION AND FOUR-
CONDUCTOR BRANCH CIRCUIT CONNECTION
When installing in new construction, or
When installing in a mobile home, or
When installing in a recreational vehicle, or
When local codes do not permit grounding through
neutral:
NOTE: If residence leads or ground are aluminum
conductors, see WARNING on page 5.
When connecting to a four-conductor branch circuit, if
local codes permit:
1. Free the neutral (white) lead from being restrained
to any other wires. If necessary, cut the neutral
(white) lead and then re-strip it to expose the proper
length of conductor.
2. Attach the appliance grounding lead (green or bare
copper) in accordance with local codes.
3. Connect the oven neutral (white) lead to the branch
circuit neutral (white or gray) in accordance with
local codes, using a wire nut.
4. Connect the oven red lead to the branch circuit red
lead and the oven black lead to the branch circuit
black lead in accordance with local codes, using
wire nuts.
5. Install proper strain relief clamp.
6. Install junction box cover.
Junction Box Cover
White
Black
Red
Branch
circuit
Ground
wires
Alternate
knockout
Range
conduit
snaps
into box
2
ELECTRICAL CONNECTIONS (Cont)
1. Turn off the circuit breaker or remove fuses to the
oven branch circuit.
2. With the oven supported on a table or platform in
front of the cabinet opening, connect the flexible
conduit to the electrical junction box as shown
below. Position the conduit in such a manner that
it will lie in a natural loop, in the conduit pocket
behind the unit, when the oven is installed. You will
need to purchase an appropriate strain relief clamp
to complete the connection of the conduit to the
junction box.
Strain Relief Clamp
(not included) must be
used at Junction Box.Place oven on a support
to assist in connecting
conduit, must support
200lbs (91kg).
Junction Box Location
Conduit
GROUND
WIRE
GROUND
RED
WHITE
BLACK