Installation Instructions
INSTALLING THE COOKTOP
[] ATTACHING A BLOWER
TRANSITION DUCT
Use a blower transition duct for all downward
duct installations to connect to 6" round
standard ductwork. This 31/4" x 10" rectangle
to 6" round transition duct is available at
your local building supply store.
Screw
(sl°_e_ther
Remove the cardboard packing in the blower
outlet.
Install the transition duct to the blower outlet.
Secure all joints with duct tape to assure an
airtight seal.
CONNECTING THE DUCTWORK
Connect the ductwork prepared in Steps 5 and
6 to the blower transition duct.
[_] BLOWER ELECTRICAL
CONNECTIONS
* Loosen the screws and remove and discard
the sheet metal strap covering the 5-pin
connector. Save the screws for reinstallation
later.
Connect the 5-pin plug on the blower
assembly to the matching 5-pin receptacle
on the bottom of the wire enclosure,
5-pin
connectors
Fold all wires into the electrical enclosure.
Secure the enclosure with the screws
removed earlier, making sure that no
wires are trapped.
S-pin
connectors
Electrical
-- -enclosure
Flexible
conduit