Installation
55
EN
2. Reposition the nozzles using a 7-mm
spanner according to the gas to be used
(see “Burner and nozzle specifications
tables”).
1 External nozzle - 2 Internal nozzle
3. Reposition the burners in their respective
housings.
Adjusting the minimum setting for natural
gas
Light the burner and turn it to the minimum
position. Extract the gas valve knob and turn
the adjustment screw next to the valve rod
(depending on the model) until the correct
minimum flame is achieved.
Refit the knob and verify that the burner
flame is stable. Turn the knob rapidly from
the maximum to the minimum setting: the
flame should not go out. Repeat the
operation on all gas valves.
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
valve rod clockwise all the way.
Lubricating the gas valves
Over time the gas valves can become
difficult to turn and get blocked. Clean them
internally and replace the lubrication
grease.
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label on the appliance with the
one corresponding to the new
type of gas. The label is inserted
inside the nozzle pack (where
fitted).
Lubrication of the gas valves be
performed by a specialised
technician.