Model: DEGH60BG Model: DEGH70BG
Model: DEGH90BG
CLEARANCES
Installation clearances and protection of combustible surfaces shall comply with the current
local regulations e.g. AS/NZS5601 - Gas Installations code.
(1) 54 mm from top of countertop.
(2) At least 60 mm between the back side of the cut-out and the back of the countertop.
(3) At least 200 mm from the periphery of the nearest burner to any vertical combustible surface.
If the distance from the periphery of the nearest burner to any vertical combustible surface,
or vertical combustible surface with toughened glass or sheet metal, is less than 200 mm, the
surface shall be protected (in accordance with AS/NZS5601) to a height of not less than 150
mm above the hob for the full dimension (width or depth) of the cooking surface area.
480
60
(2) (3)
560
715
510
54
(1)
840
869
480
510
60
(2) (3)
54
(1)
480
60
(2) (3)
560
585
510
54
(1)
Important note:
This appliance shall not be used as a space heater, especially if installed in marine craft
or caravans.