GAS SUPPLY
This appliance is suitable for use with Natural Gas or ULPG (Check the “gas type”
sticker attached to the appliance).
For Natural Gas the gas supply must be regulated to obtain a pressure of 1 kPa with
the two semi-rapid (SR) burners operating at the maximum.
For ULPG models connect the gas supply directly to the appliance test point adaptor
(supplied with the conversion kit) and ensure that the supply pressure is regulated to
2.75 kPa.
Do NOT force the ”elbow“ rotation prior to loosening nut.
Do NOT over tighten the nut at the ”elbow“.
1. After connecting the gas supply, check the piping and connections for leaks using a
soap and water solution. The presence of bubbles indicates a leak, tighten or replace
connections as appropriate.
Warning: 
2. The operation of the appliance MUST be tested before leaving.
3. Adjust the test point pressure or supply pressure to the value which is appropriate for
the gas type.
4.       

burner cap is located properly and the injector nipple is aligned correctly.
NL
(
)
L
Figure 8a Figure 8b