Safety Tips
14 / 24
Number: JT190199989 Version Number: A1
Note: Subsequent versions of this specification are subject to change without prior notice. Thank you
Cleaning and disinfection
Stop, start draining
30 s after completion of drainage;
Enter the automatic rinsing phase, clean for 3
minutes before draining
30 s, After 5 cycles of rinsing process, the whole
cleaning process is completed
Beam, screen display "OFF", into standby state,
the whole process
It takes about 37 minutes;
5.
Unplug the power.
6. Remove flow pipe, water retaining plate, take
out water pump, float ball, ice shovel (removal
method refer to parts removal / installation
process).
7.
Mix 8 liters of warm water (45~50℃) and 4
packets of cleaning agent (KAY
DELIMER ,56.7g/ package) into cleaning
liquid (the amount of cleaning liquid needs to
be adjusted appropriately).
8.
Soak the parts in the cleaning solution for more
than 5 minutes (if the scale is heavy, it is
recommended to soak for more than 10
minutes).
9.
While soaking parts, wipe the surface of parts
in contact with water and ice with nylon brush
or soft cloth dipping cleaning liquid, such as
evaporator ice grid, ice baffle, ice storage
bucket, etc .(the dead corner can be dipped in
cleaning agent wet rag wrapped disposable
chopsticks cleaning). Rinse with clean water
(5 times).
Scrub the ice shield
Wash the refrigerator
Loading ...