Back wall
alcove return
Floor
PROFILE VIEW
INSTALL ANTI-TIP BRACKET
Anti-tip bracket
assembly kit
Anti-tip bracket
(1)
Masonry plug
(4)
#10x40 cross-head
screw (4)
Tools
Cross-head screwdriver
Powered drill
Pencil
Leveler
Safety glasses
screws
For plaster board wall installation
Fix bracket to wall with 10x40mm cross
head screws (4x), and screw tightly with
a screwdriver.
5
For solid wall installation
Hammer 10x30mm masonry plugs into wall until
flush. Fix bracket to wall with 10x40mm cross head
screws (4x), and screw tightly.
6
IMPORTANT!
Ensure the bracket overlaps the appliance by a minimum 7 1/16" (min 180mm) for a secure hold. If the minimum
7 1/16" (180mm) overlap cannot be achieved, install a solid spacer to the wall screw behind the bracket.
7 1/16"
(min 180mm)
Bracket
Appliance
Back wall
Bracket
Spacer
Appliance
Back wall
7 1/16"
(min 180mm)
Mark a horizontal line on the back wall
based on measured attachment height.
Ensure there is a stud behind the wall.
2
Mark screw hole locations, and drill
screw holes with powered drill.
4
Place the bracket to the backwall.
Align the undersurface of bracket
along the marked line.
3
stud
Measure height from floor to alcove return (A). Use this
measurement to locate the attachment height (B) of
anti-tip bracket to the back wall.
z
Attachment height of anti-tip bracket should
not be more than 84 3/16" (2138mm) to ensure
the appliance is prevented from tipping over
during installation.
1
B
A
7 3/4"
(min 197mm)
bracket
masonry plugs
Loading ...