STACKED WASHER/GAS DRYER iNSTALLATiON
REQUIREMENTS
Stacked Washer/Gas Dryer Electrical Requirements Stacked Washer/Gas Dryer Gas Supply
I M PORTANT: The washer/dryer must be electrically grounded
in accordance with local codes and ordinances or, in the
absence of local codes, with the Canadian Electrical Code, CSA
C22.1. If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
lu Do not ground to a gas pipe.
lu Do not have a fuse in the neutral or ground circuit.
In A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this washer/dryer be provided.
In If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
In Check with a qualified electrician if you are not sure the
washer/dryer is properly grounded.
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut=off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (330 ram) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Stacked Washer/Gas Dryer Grounding
GROUNDING INSTRUCTIONS
For a permanently connected washer/dryer:
This appliance must be connected to a grounded metal,
permanent wiring system, or an equipment grounding
conductor must be run with the circuit conductors and
connected to the equipment=grounding terminal or lead
on the appliance.
WARNING" Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the appliance
is properly grounded.
SAVE THESE INSTRUCTIONS
I MPORTANT: Observe all governing codes and ordinances.
This installation must conform with all local codes and ordinances.
In the absence of local codes, installation must conform with CAN/
CSA B149.
A copy of the above code standards can be obtained from:
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
The design of this washer/dryer has been certified by CSA
International for use at altitudes up to 10,000 feet (3048 m) above
sea level at the B.T.U. rating indicated on the model/serial plate.
Burner input adjustments are not required when the washer/dryer
is operated up to this elevation.
When installed above 10,000 feet (3048 m), a four percent (40/0)
reduction of the burner B.T.U. rating shown on the model/serial
plate is required for each 1,000 foot (305 m) increase in elevation.
For assistance when converting to other gas types and/or installing
above 10,000 feet (3048 m) elevation, contact your local service
company.