Maytag MLG20PRCWW1 stacked laundry center

User Manual - Page 11

For MLG20PRCWW1.

PDF File Manual, 64 pages, Download pdf file

Loading ...
Loading ...
Loading ...
STACKED WASHER/ELECTRIC DRYER iNSTALLATiON
REQUIREMENTS
Stacked Washer/Electric Dryer Electrical
Requirements
Washer Electrical Requirements
Do not have a fuse in the neutral or ground circuit.
m If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that
the ground path is adequate.
m Check with a qualified electrician if you are not sure the washer
is properly grounded.
Stacked Washer/Electric Dryer Grounding
GROUNDING iNSTRUCTiONS
For a permanently connected washer/dryer:
This appliance must be connected to a grounded metal,
permanent wiring system, or an equipment grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead
on the appliance.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the appliance
is properly grounded.
SAVE THESE iNSTRUCTiONS
Dryer Electrical Requirements
It is your responsibility:
m To contact a qualified electrical installer.
m To be sure that the electrical connection is adequate and in
conformance with the Canadian Electrical Code.
The Canadian Electrical Code requires a 4-wire power supply
connection.
m To supply the required 4 wire, single phase, 240 volt, 60 Hz.,
AC only electrical supply (or 4 wire, 120/208 volt electrical
supply, if specified on the serial/rating plate) on a separate
40-amp circuit, fused on both sides of the line. A time delay
fuse or circuit breaker is recommended. Connect to an
individual branch circuit. Do not have a fuse in the neutral
or grounding circuit.
m Do not use an extension cord.
m If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical Connection
This dryer is supplied/fitted with an electrical
supply cord and plug. It should be connected
to a 4-wire electrical supply receptacle of
NEMA Type 14-50P, at the voltage shown
on the rating plate. The dryer must be
positioned so that the plug is clearly visible and
accessible. This plug also provides the function
of an emergency stop control for the user. If the
fitted plug is not used, the electrical connection
4-Wire Receptacle
(14-50P)
must be carried out by a competent electrician in accordance with
local or national codes.
If the supply cord is damaged, it must be replaced with a specially
terminated cord by an authorized service agent or a similarly
competent person in order to avoid a hazard.
11
Loading ...
Loading ...
Loading ...