DRYER VENTING REQUIREMENTS
Vent Hoods
4" (102 mm) Diameter Exhaust Hoods
Box Hood Louvered Hood Angled Hood
Exhaust hood must be at least 1 2" (305 mm) from the ground or
any object that may be in the path of the exhaust (such as flowers,
rocks, bushes, or snow).
Vent System Length
Maximum Vent Length/Vent Connection
Maximum length of vent system depends upon the type of vent
used, number of elbows, and type of exhaust hood.
3. Tighten hose clamp with Phillips screwdriver.
Vent System Chart (Rigid Metal Vent)
No. of Box and Angled
90 ° Turns Louvered Hood Hood
0
1
2
3
4
135 ft. (41.2 m)
125 ft. (38.1 m)
115 ft. (35.1 m)
106 ft. (32.3 m)
98 ft. (29.9 m)
129 ft. (39.3 m)
119 ft. (36.3 m)
109 ft. (33.2 m)
100 ft. (30.5 m)
92 ft. (28.0 m)
\
For vent systems not covered by the vent specification chart, see
your parts distributor.
Provision must be made for enough air for combustion and
ventilation. (Check governing codes and ordinances.) See
"Recessed Area Installation Instructions" in the "Stacked Washer/
Gas Dryer Location" and "Stacked Washer/Electric Dryer
Location" sections.
A 4" (102 mm) outlet hood is preferred. However, a 21/2'' (64 mm)
outlet exhaust hood may be used. A 21/2'' (64 mm) outlet creates
greater back pressure than other hood types. For permanent
installation, a stationary vent system is required.
Connect Vent
1. If connecting to existing vent, make sure the vent is clean.
2. Using a 4" (102 ram) clamp, connect vent to exhaust outlet in
dryer.
jyvoo, oo,,o,
4. Make sure the vent is secured to exhaust hood with a 4"
(102 ram) clamp.
5. Move dryer into final position. Do not crush or kink vent. Make
sure dryer is level.
NOTE: Do not remove vent collar.
13