Ashley AP5780E 2,200 Sq. Ft. Pellet Stove with Black Curved Sides

User Manual - Page 4

For AP5780E. Also, The document are for others Ashley models: 5780*

PDF File Manual, 48 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
-4-
INSTALLATION OPTIONS
Read this entire manual before you install and use your pellet stove. Failure to follow instructions may result
in property damage, bodily injury, or even death! See specic installation details for clearances and other
installation requirements.
Freestanding Unit - supported by pedestal/legs and placed on a non-combustible oor surface in compliance
with clearance requirements for a freestanding stove installation.
Your pellet stove may be installed to code in either a conventional or mobile home (see Special Mobile Home
Requirements). It is recommended that only a authorized technician install your pellet stove, preferably an NFI
certied specialist. DO NOT CONNECT THIS UNIT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. The use of other
components other than stated herein could cause bodily harm, heater damage, and void your warranty.
IMPROPER INSTALLATION
The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper
venting or installation. Call (800) 750-2723 and/or consult a professional installer if you have any questions.
CLEARANCES
Your pellet stove has been tested and listed for installation in residential, mobile home in accordance with the
clearances given below. For safety reasons, please adhere to the installation clearances and restrictions. Any
reduction in clearance to combustibles may only be done by means approved by a regulatory authority.
in mm
A Side Wall to Stove 8 204
B Side Wall to Vent Pipe 12 305
C Back Wall to Stove 12 305
D Back Wall to Vent Pipe 3 77
E Ceiling to Floor 84 2134
F Ceiling to Stove 46.875 1191
G Side Wall to Stove 10 254
H Side Wall to Vent Pipe 3 77
J Back Wall to Stove 10 254
K Back Wall to Vent Pipe 3 77
Installation
K
J
G
H
ADJACENT WALL
ADJACENT WALL
C B
A
E
F
D
in mm
L Back to Stove
USA 1 26
CAN 8 204
M Side to Stove
USA 6 153
CAN 8 204
N Front to Stove
USA 6 153
CAN 8 458
P Back and Sides to Flue 6 153
FLOOR PROTECTION
This heater must have a non-combustible oor protector (UL1618 ember protection) installed beneath it if the
oor is of combustible material. US: Floor protector should be UL listed or equal too, needs to extend 16” to the
front, 8” to each side, 1” to the rear of the unit. Under and 2” beyond each side of the cleanout tee if an interior
vertical instillation. Canada: Floor protector should comply with CAN/ULC standards. Needs to extend 18” to the
front, 8” beyond each side of the unit.
L
M M
N
THROUGH THE WALL
INSTALLATION
P
INTERIOR VERTICAL INSTALLATION
Loading ...