INSTALLATION INSTRUCTIONS
Drain pump
The drain pump is designed to remove drain water from ice makers installed in areas
without direct drainage access. The sealed reservoir pump collects the melted ice water
and pumps it to a maximum lift of 8ft (2.44m) through 3/8” I.D. vinyl tubing to adrain.
Note: this pump has been evaluated for use with water only.
Note: reasonable care and safe methods should be practiced. Do not work with
energized electrical equipment in a wet area. Read and follow the installation
instructions listed in this manual.
WARNING!
Risk of electric shock — This pump is supplied with a grounding conductor and
grounding-type attachment plug. To reduce the risk of electric shock, be certain that
it is connected only to properly grounded, grounding-type receptacle.
Maintenance
The following items require review on a regular basis:
Check that the vent line is open, free of kinks/sharp bends, so that air flows freely from
the pump reservoir.
Check that the discharge tubing is free of foreign material (algae, etc) and kinks/bends.
Confirm that the check valve is operational by observing that the water flow is evident
in one direction only — out of the pump. Remove and clean as required.