2.
Loosen or remove center silver-colored terminal block screw.
Place the hooked end of the neutral wire (white or center wire)
of direct wire cable under the center screw of terminal block
(hook facing right). Squeeze hooked end together. Tighten
screw.
Optional 3-wire connection
Use for direct wire or power supply cord where local codes
do not permit connecting cabinet-ground conductor to
neutral wire.
1. Remove center silver-colored terminal block screw.
2. Remove neutral grounding wire (green with yellow stripes)
from external ground conductor screw. Connect neutral
grounding wire (green with yellow stripes) and the neutral wire
(white or center wire) of power supply cord/cable under
center, silver-colored terminal block screw. Tighten screw.
A. External ground conductor screw
B. Neutral grounding wire (green with yellow stripes)
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E. _" (!.9 cm) UL listed strain relief
Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now, go to
"Venting Requirements."
A. External ground conductor screw
B. Center silver-colored terminal block screw
C. Neutral grounding wire (green with yellow stripes)
D. Neutral wire (white or center wire)
E. _" (!.9 cm) UL listed strain relief
F Grounding path determined by a qualified electrician
Connect the other wires to outer terminal block screws.
Tighten screws.
!! !!
D
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. Connect a separate copper ground wire from the external
ground conductor screw to an adequate ground.