Commissioning
7.1 Verify Electronic Operation
After the plumbing of the cylinder has been fully
commissioned and the appliance connected to a
suitable electrical supply, the electrical supply to
the unit can be turned on.
The user interface should power up and a battery
symbol and temperature should be visible on the
display screen.
The user interface consists of the following
components as shown:
Figure 11: User Interface
1. Display Screen
2. “Menu” Button
3. “Back” Button
4. Advance” Button
5. “Selector Dial”
1
3
44
45
2
7.2 Initialise System Settings and
Communications
The system settings of the cylinder can now be
veried,andorchanged.Toaccesstheservice
menu of the appliance the back button, menu
button and selector dial, should be pressed for 10
seconds.
- Enter the service menu.
- Ensure that reset is highlighted, and press the
selector dial.
- Select using the selector dial if you want to reset
the temperature log, the energy log or the full
system to the factory defaults. Once the required
option is highlighted press and hold the selector
dial for 5 seconds (see Figure 12 for how to
access the reset function).
7.2.6 Reset
- Enter the service menu.
- Rotate the dial to select hygiene and press the
dial to select
- Hygiene mode can be set to either Daily, Weekly,
Monthly or Off temperature for hygiene mode
operation can then be set between a range of
60-68˚C(seeFigure12forhowtoaccessthe
hygiene function).
7.2.2 Set Hygiene Mode
The water can be controlled by the utility via the
RF module installed. Where this communication
mode is not available the unit can be operated
in standalone mode (i.e. when communications
with the utility are cut off, the cylinder operates in
standalone mode). In this mode the heater tries
to achieve 60°C at T1 and tries to maintain this
throughout the day. The communications of the
appliance can be changed as shown in Figure 12.
7.2.3 Set Communication Mode
The water can be controlled by the utility via the
RF module installed. Where this communication
mode is not available the unit can be operated
in standalone mode (i.e. when communications
with the utility are cut off, the cylinder operates in
standalone mode). In this mode the heater tries
to achieve 60°C at T1 and tries to maintain this
throughout the day. The communications of the
appliance can be changed as shown in Figure 12.
7.2.4 Set Cylinder Size
Calibration of the Real Time Clock is performed on
initial commissioning and should not be required
by the user unless changes are required to the
electronic components on the cylinder.
7.2.5 RTC Calibration
- Enter the service menu.
- Rotate the dial to select tariff and press the dial
to select.
- The tariff can be set to either Off-peak or Timed.
- Off Peak tariff heats the cylinder using the
bottom immersion heater to the primary
set-point whenever an off peak power supply is
available. Section Figure 7 for wiring
conguration.
- Timed tariff requires that time period is set
during which the cylinder will be heated to the
primary temperature set-point. This heat up or
charge period on the cylinder to be aligned with
any low cost energy tariff available. See Figure 8
forwiringconguration.
7.2.1 Set Tariff
7.3 ConrmationofOperation
Operationofthecylindershallbeconrmedwith
a cold tank, use a current tester or verify that the
outlet pipe feels warm within 1hr of start-up.
Note: This should only be attempted if the
insulation may be disturbed slightly without
damage.