6
CONDENSATE RESERVOIR TANK
For Air Boss Models PAC12, PAC18, PAC24 and PAC36, a 5-gallon polyethylene tank is
provided standard, to collect condensate. The tank is located in the lower, front section
of the unit. A high water level cut-out switch is used to stop the compressor and
condenser fan automatically when the tank's pre-set water level has been reached. The
evaporator fan will continue to run, circulating air.
TANK LEVEL ADJUSTMENT INSTRUCTIONS
An adjustment screw is provided to vary the cut-off of the tank full switch. If a lighter (less
weight) level of water is desired, turn the adjusting screw clockwise. Do not exceed 6 full
turns counter-clockwise.
CAUTION, TURN UNIT OFF: BEFORE ADJUSTING SET SCREW
BEFORE REMOVING TANK TO EMPTY CONDENSATE
Turn screw clockwise to lower water level. Less water makes tank lighter and easier to
remove.
NOTE: Max. and Min. water levels shown are those at which the unit will shutdown and
not restart until the condensate tank has been drained.
Condensate Tank
*Tank Water Level
Adjusting Screw
Spring
Handle
For PAC36 —
Condensate
drains
through a
corrugated
hose into
tank cap
High Water Level
Cut-Out Switch
Condensate
Tank Tray
Max Water
Level
4" From Top
For PAC12, PAC18
and PAC24 —
Condensate water
drops from drain pan
into trough on tank