5. System Health Check / Maintenance
NOTE: These are checks that should be carried out regularly to ensure that your Dimplex product
performs at its best.
5.1 Heat pump:
Is the fan grille clear from debris? - Visual check
Is the tray clear from debris and water owing freely? - Visual check
Is the condensate drain clear from debris?
Is the evaporator coil clean and free from damage? E.g. attened ns
Are all of the outer panels secure?
5.2 Electrical:
Is the power cable rmly xed?
Is the earth wire connection secure?
Is the supply voltage correct?
5.3 Hydraulics:
Is the system correctly pressurized?
Are there any water leaks in the system? Is the required pressure holding?
Is the strainer on the return pipe clear of debris?
See section 4.1.3 for details on isolating and cleaning the strainer.
5.4 Indoor settings:
Are the set temperatures and heating times suitable for the occupants?
Is the building warm enough for the occupants or does the heating curve need to be adjusted?
NOTE: It is recommended that the strainer is checked and cleaned 24 hours after commissioning, and
each time the system is modied or has service work carried out thereafter.