13
A. White wires
B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/
green wires
E. Home power supply
F. UL listed or CSA
approved 1/2" (1.3 cm)
strain relief
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
3. Use UL listed wire connectors and connect black wires (B)
together.
4. Use UL listed wire connectors and connect white wires (A)
together.
NOTE: When using an in-line blower motor system, the green (or
green/yellow) ground wire in the conduit from the in-line blower
motor system is to be connected with the green (or bare) wire of
the home power supply cable and with the green/yellow wire (D)
in the terminal box.
5. Connect green (or bare) ground wire from home power
supply to the green/yellow ground wire (D) in terminal box
using UL listed wire connectors.
6. Install terminal box cover.
7. Check that all light bulbs are secure in their sockets.
8. Reconnect power.
Install Chimney Covers
Connect the vent system and seal all connections with clamps.
Install Upper Chimney Cover
1. Slightly spread the sides of the cover apart and hook them
behind the chimney mounting brackets.
2. Attach the cover to the brackets with 2 - 4.2 x 8 mm screws.
3. Securely tighten screws.
Install Lower Chimney Cover
1. Slightly spread the sides of the cover apart and hook them
behind the upper chimney.
2. From inside the range hood, use the 4 – 4.2 x 8 mm screws
to attach the lower chimney cover to the body of the range
hood.
3. Securely tighten screws.
Complete Installation and Check
Operation
1. Install grease  lters. See the “Range Hood Care” section.
2. Check operation of the range hood blower and lights. See
the “Range Hood Use” section.
3. If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power supply and check that the wiring is
correct.
NOTE: To get the most ef cient use from your new range
hood, read the “Range Hood Use” section.
A
B
C
D
E
F
A
A
A. Two 4.2 x 8 mm screws
A
A
A. Screws
B
C
D
A
E
A. Blower control switches
B. LED lights
C. Grease lter handles
D. Grease lter
E. Heat lamps