Connect Vent System
1. Install transition on top of hood (if removed for shipping)
with(2) 3.5 x 9.5 mm sheet metal screws.
A. Vent transition
B. 3.5 x 9.5 mm screw
A
B
For vented installations only:
1. Fit vent system over the exhaust outlet.
2. Seal connection with clamps.
3. Check that back draft dampers work properly.
Install Range Hood
NOTE: Remove protective lm from range hood and metal lters.
1. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
2. Remove the grease lter. See “Range Hood Care” section.
3. Level the range hood and tighten upper mounting screws.
4. Install (2) 5 x 45 mm lower mounting screws and tighten.
Usethe optional wall anchors if needed.
For non-vented (recirculating) installation only:
1. Assemble the air deector with the duct cover bracket
using(4) 4 x 8 mm screws.
2.
A
B
C
A. Assembly screws
B. Air deector
C. Duct cover bracket
Measure from the bottom of the air deector to the bottom
ofthe hood outlet.
X
A
C
D
B
E
A. Air deector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
3. Cut the duct to the measured size “X.”
4. Remove the air deector.
5. Slide the duct onto the bottom of the air deector.
6. Place the assembled air deector and duct over
theexhaustoutlet from the hood.
7. Reassemble the air deector to the duct cover
bracketwiththe 4 assembly screws.
8. Seal connections with vent clamps.