CYLINDER SIZE OPENING A AREA OPENING B AREA
20in
2
2
10in
2
2
2
2
15in
2
2
5” (127mm)
MAXIMUM
1” (25.4mm)
MAXIMUM
OPENING
A
OPENING
B
2” (51mm)
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
NON LOCKING DOOR
34” (864mm)
RECOMMENDED
5” (127mm)
MAXIMUM
-
used to enclose the gas grill. A propane cylinder can not be stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must
have both of the following:
2
2
2
2
Every opening must be large enough to permit the entrance of a 1/8 in (3.2 mm) rod.
WARNING!
• The cylinder valve(s) must be readily accessible for hand operaon. A door on the enclosure to
gain access to the cylinder valves is acceptable, provided it is non-locking and can be opened
without the use of tools.
• The enclosure for the LP-gas cylinder must isolate the cylinder from the burner compartment to
provide shielding from radiaon, a ame barrier, and protecon from foreign material, such as
hot drippings. The enclosure cannot be located directly below the grill.
• There must be a minimum clearance of 2 in (51 mm) between the oor of the LP-gas cylinder
enclosure and the ground.
• The enclosure must be designed so that the LP-gas cylinder can be connected, disconnected and
the connecons inspected and tested outside the cylinder enclosure. Any connecons that can
be disturbed when installing the cylinder in the enclosure must be accessible for tesng inside the
enclosure.
!