Simer 3305P 1/2 HP Convertible Well Pump

User Manual - Page 9

For 3305P. Also, The document are for others Simer models: 3325E, 3327E, 3307P, 3310P

PDF File Manual, 48 pages, Read Online | Download pdf file

3305P photo
Loading ...
Loading ...
Loading ...
Electrical 9
For parts or assistance, call Simer Customer Service at 1-800-468-7867
Dial Type Voltage Selector
Voltage is set to 230 volts. To change to 115 volts:
1. Make sure power is off.
2. Turn the dial counter-clockwise until 115 shows in
the dial window as shown in Figure 15.
3. Attach the incoming power leads to the two outer
screws on the pressure switch as shown in Figure 14.
4. Attach the ground wire to the grounding connections
as shown in Figure 14.
5. If there are other wires, they should be capped.
6. Reinstall the Motor end cover.
Hazardous voltage. Can shock, burn, or
kill. Connect ground wire before connecting power
supply wires. Use the wire size (including the ground
wire) specified in the wiring chart. If possible, connect
the pump to a separate branch circuit with no other
appliances on it.
Explosion hazard. Do not ground to a gas
supply line.
Figure 14: Voltage set to 230 volts, Dial Type
Ground Wire Connection
Power Supply Connections
Voltage
Change
Dial
Pressure Switch
Figure 15: Voltage set to 115 volts, Dial Type
Disconnect power before working on pump, motor, pressure switch, or wiring.
Motor Switch Settings
NOTICE: 1/2 HP motors are dual voltage and are factory set to 115V. 3/4 & 1 HP motors are also dual voltage, but are
factory set to 230V. Motor terminal board (located under the motor end cover) should look like that shown below. Use
the instructions to set your motor to match your power source.
Never connect a motor set to 115V to a 230V power source.