Discharge Pipe and Pressure Tank Connections 8
For parts or assistance, call Simer Customer Service at 1-800-468-7867
Pre-Charge Tank Connection (Figure 12)
1. Install a close nipple and a tee in the pump discharge port (see
Figure12). The pipe size must be at least as large as the discharge port.
Run a pipe or reinforced hose from one arm of the tee to the port on
the pre-charged tank.
2. Install a second close nipple and tee with a relief valve in the tee.
3. Connect the other end of the second discharge tee to your
plumbingsystem.
4. Check the pre-charge of air in the tank with an ordinary tire gauge. The
pre-charge should be 2 PSI less than the cut-in setting of the pump’s
pressure switch. The pre-charge is measured when there is no water
pressure in the tank. Your new pump has a 30/50 PSI switch, so adjust
the tank pre-charge pressure to 28 PSI.
You have just completed the tank connection for your jet pump. Please go
to Pages 9 and 10 for electrical hookup.
Standard Tank Connection (Figure 13)
1. Install a close nipple and a tee in the pump discharge port. Mount a
relief valve in one arm of the tee.
2. Install a second close nipple and tee in the open arm of the first tee. Put
a priming plug in one arm of the second tee.
3. Run a pipe from the open arm of the second tee to the inlet port of your
tank. The pipe size must be at least as large as the pump dischargeport.
4. Remove the 1/8” NPT pipe plug from the pump Air Volume Control
(AVC) port (see Figure 13). Run tubing from the pump’s AVC port to the
port on the AVC mounted on the tank. See instructions provided with
tank and AVC for details.
You have just completed the tank connection for your jet pump. Please go
to Pages 9 and 10 for electrical hookup.
To Household
Water System
Pressure Gauge
and Priming
Plug
Pressure
Switch
From
Well
Relief
Valve
To Household
Water System
Pressure
Switch
From
Well
Air Volume
Control
Air Volume
Control Tube
Priming Tee
and Plug
Relief Valve
Figure 12: Pre-charged Tank
Connections
Figure 13: Standard Tank Connections
Sealing Pipe Joints
Use only
1
Teflon™ tape or Teflon™ based joint compounds
for making all threaded connections to the pump itself. Do not
use pipe joint compounds on plastic pumps: they can react
with the plastic in pump components. Make sure that all pipe
joints in the suction pipe are air tight as well as water tight. If
the suction pipe can suck air, the pump will not be able to pull
water from the well.