Napoleon NEFB33H Ascent Electric 33

User Manual - Page 16

For NEFB33H.

PDF File Manual, 68 pages, Read Online | Download pdf file

NEFB33H photo
Loading ...
Loading ...
Loading ...
RED
GREEN
BLACK
WHITE
GREEN (G)
RED (L2)
BLACK (L1)
WHITE (N)
240V HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualifi ed electrician must remove the cord connection, and wire the
appliance directly to the household wiring. The wire and double-pole power supply breaker must rated for 240V
minimum 15 Amps, maximum 20 Amps.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In the
absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current
ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
RED
GREEN
BLACK
WHITE
GREEN (G)
RED (L2)
BLACK (L1)
WHITE (N)
115
White, Black, Red and
Green wires:
Connect to 240V
power supply.
3.3.6 240V hard wiring installation
Wire Nut
W415-2165 / J / 04.28.2020
EN
16
installation
Voltage Selector Switch
230
Turn off the appliance completely and let cool before servicing. Only a qualifi ed service person should service
and repair this electric appliance.
!
WARNING
There are 4 wires from the appliance junction: white (neutral), black (power L1), Red (Power L2) and green
(ground) that connect to 240V double-pole power supply (breaker panel).
note: