Napoleon NEFB33H Ascent Electric 33

User Manual - Page 14

For NEFB33H.

PDF File Manual, 68 pages, Read Online | Download pdf file

NEFB33H photo
Loading ...
Loading ...
Loading ...
BLACK
WHITE
GREEN
BLACK (L1)
WHITE (N)
RED
GREEN (G)
120V HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualifi ed electrician must remove the cord connection, and wire the
appliance directly to the household wiring. The wire and power supply breaker must be rated for 120V minimum
15 Amps.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In the
absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current
ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
BLACK
WHITE
GREEN
BLACK (L1)
WHITE (N)
RED
GREEN (G)
115
White, Green and
Black wires:
Connect to 120V
power supply.
3.3.5 120V hard wiring installation
Voltage Selector Switch
Wire Nut
W415-2165 / J / 04.28.2020
EN
14
installation
115
Turn off the appliance completely and let cool before servicing. Only a qualifi ed service person should service
and repair this electric appliance.
!
WARNING
There are 4 wires from the appliance junction: white (neutral), black (power L1), Red (Power L2) and green
(ground) that connect to 120V power supply (breaker panel).