installation
3.3.3 voltage selector switch location
The voltage selector switch is located inside the appliance (Fig. 1).
A. Remove the glass door (see "glass door removal and installation" section).
B. Remove metal cover from the voltage selector switch.
C. Change the voltage selector switch position.
230
Fig.1
When wiring the appliance for 240 volt, the voltage selector switch should be in 230 volt position on the switch.
3.3.4 120 volt cord plug installation
The factory default setting is 120 volt cord plug installation confi guration. Simply plug the appliance to a
grounded 120V 15 Amp outlet box.
Voltage Selector Switch
Factory default setting is 120 volt (115 printed on the switch) if you use 120 volt power supply you do not
need to make the changes.
note:
Must be connected to a dedicated 15 Amp circuit. The use of an extension cord is NOT permitted.
note:
The voltage selector switch must match the incoming power supply voltage. The heater will overheat if the
switch does not match the incoming power supply voltage.
When changing the voltage selector switch from 240 volts to 120 volts (or vice versa), the power supply must
be turned off fi rst.
!
WARNING