Instructions for the Installer
EN
47
Use grounding terminal or lead to ground unit; and
Connect neutral terminal or lead to branch circuit neutral in usual manner.
16.4 3-Wire branch circuit (for US only)
Refer to the following Figure, where local codes allow
the connection of GROUND wire from the oven to the
branch circuit NEUTRAL wire (gray or white colored
wire):
If local codes permit, connect the green GROUND wire from the oven and
the white wire from the oven to the branch circuit NEUTRAL wire (gray or
white colored wire).
Connect the red and black leads from the oven to the corresponding leads in
the junction box.
16.5 4-Wire branch circuit (for US and CANADA)
Refer to the following Figure:
Disconnect ground from neutral at free end of conduit.
Connect the green GROUND wire from the oven to the GROUND wire in the
junction box (bare or green colored wire).
Connect the red and black leads from the oven to the corresponding leads in
the junction box.