EN
Instructions for the User
16
Press PT1 to confirm the water hardness level.
TYPE
WATER HARDNESS
disp 1
Ca + Mg
(ppm)
English deg.
[°eH]
French deg.
[°dF]
German deg.
[°dH]
SOFT WATER
0 TO 150
0 TO 11
0 TO 15
0 TO 8
SOFT
MEDIUM WATER
151 TO 350
12 TO 25
16 TO 35
9 TO 20
MED
HARD WATER
351 TO 500
26 TO 35
36 TO 50
21 TO 28
HARD
6.3.2 Water Level calibration
After setting the water hardness, appears in the Display and the
water level lights shine.
Please take the Water tank completely off. Wait until the display and the
water tank lights disappear.
6.3.3 Changing the current time
It might become necessary to change the current time, for example at the
switch from summer to winter time. To do this, starting from the standby
setting (see point “Operating settings”) keep PT1 pressed for a few
seconds until the figures on DSP1 flash. Now repeat the operations
described in point “Setting the current time and water hardness level”.
6.3.4 Changing the current water hardness level
It might become necessary to change the current water hardness level. To
do this, please refer to point “10.3.3 changing the water hardness level”.
7 WATER FEEDING
All steam functions require the water tank to be full.
Fill the water tank up with cold, fresh drinking water (approximately 4 cups
/ 1 liter) and introduce it into the slot located above the cavity until you
hear a click.
If the indication “rES” appears, it means that the water tank was not
properly inserted.
7.1 Refilling the water
The contents of the water tank normally suffice for one cooking session of
aprox. 50 minutes.
If, however, the water tank needs to be refilled, the water refill light starts
to flash . Only fill the water tank
up to a maximum of 2 CUPS to
ensure that the water does not
overflow when it is pumped back to
the water tank. RISK OF
OVERFLOW.