The nozzles not provided are available at Authorised Service Centres.
8 Liquid gas – G30/31 - 30/37 mbar AUX SR FB R UR2
Rated heating capacity (kW)
1.05 1.8 1.9 3.0 4.2
Nozzle diameter (1/100 mm)
50 65 68 85 91 + 46
Pre-chamber (printed on nozzle)
-----
Reduced flow rate (W)
400 500 800 800 1900
Rated flow rate G30 (g/h)
76 131 138 218 305
Rated flow rate G31 (g/h)
75 129 136 214 300
9 LPG G30/31 - 37 mbar AUX SR FB R UR2
Rated heating capacity (kW)
1.05 1.8 1.9 3.0 4.2
Nozzle diameter (1/100 mm)
50 65 68 81 85 + 46
Pre-chamber (printed on nozzle)
-----
Reduced flow rate (W)
450 550 800 800 1900
Rated flow rate G30 (g/h)
76 131 138 218 305
Rated flow rate G31 (g/h)
75 129 136 214 300
10 LPG G30/31 - 50 mbar AUX SR FB R UR2
Rated heating capacity (kW)
1.05 1.8 1.9 3.0 4.2
Nozzle diameter (1/100 mm)
43 58 60 70 70 + 43
Pre-chamber (printed on nozzle)
(H2) (M) (Z) (Y) (S1) + (H2)
Reduced flow rate (W)
400 500 800 800 1900
Rated flow rate G30 (g/h)
76 131 138 218 305
Rated flow rate G31 (g/h)
75 129 136 214 300
11 Town gas G110 – 8 mbar AUX SR FB R UR2
Rated heating capacity (kW)
1.05 1.8 1.9 3.0 3.8
Nozzle diameter (1/100 mm)
145 185 190 260 320 + 140
Pre-chamber (printed on nozzle)
/8 /2 /2 /3 -
Reduced flow rate (W)
400 500 800 800 1400
12 Town gas G120 – 8 mbar AUX SR FB R UR2
Rated heating capacity (kW)
1.05 1.8 1.9 3.0 3.9
Nozzle diameter (1/100 mm)
135 175 180 240 290 + 130
Pre-chamber (printed on nozzle)
/8 /1 /2 /3 -
Reduced flow rate (W)
400 500 800 800 1400