4 49-50300-2
SAFETY INFORMATION
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
Time/Temperature Relationship in Scalds
Temperature Time to Produce a Serious Burn
120°F (49°C) More than 5 minutes
125°F (52°C) 1-1/2 to 2 minutes
130°F (54°C) About 30 seconds
135°F (57°C) About 10 seconds
140°F (60°C) Less than 5 seconds
145°F (63°C) Less than 3 seconds
150°F (66°C) About 1-1/2 seconds
155°F (68°C) About 1 second
Table courtesy of Shriners Burn Institute
!
The chart shown above may be used as a guide in determining the
proper water temperature for your home.
DANGER
There is a Hot Water SCALD Potential if the
control water temperature is set too high. Households with
small children, disabled or elderly persons may require a
120°F (49°C) or lower thermostat setting to prevent contact
with “HOT” water.
Thermostat has been set at the factory to 120°F (49°C) to
reduce the risk of scald injury. This is the recommended starting
temperature setting, but it can be adjusted to any temperature
between 100°F and 140°F (38°C and 60°C).
To Adjust the Temperature
Follow these steps:
1. Press the UP or DOWN arrow on the control panel key pad to
desired temperature.
2. Press ENTER to accept the new setting.
Note: To change between °F and °C, press and hold MODE.
WATER TEMPERATURE ADJUSTMENT
Safety, energy conservation, and hot water capacity are factors
to be considered when selecting the water temperature setting
of the water heater. Water temperatures above 125°F can cause
severe burns or death from scalding. Be sure to read and follow
the warnings outlined on the label pictured below. This label is also
located on the water heater near the top of the tank.
The water heater is equipped with a temperature-limiting control
(TCO) that is located above the heating element in contact
with the tank surface. If for any reason the water temperature
EHFRPHVH[FHVVLYHO\KLJKWKHWHPSHUDWXUHOLPLWLQJFRQWURO
(TCO) breaks the power circuit to the heating element. Once
the control opens, it must be reset manually. Resetting of the
temperature limiting controls should be done by a qualified
service technician.
CAUTION
The cause of the high temperature
condition must be investigated by a qualified service
technician and corrective action must be taken before
placing the water heater in service again.
To reset the temperature-limiting control:
1. Turn off the power to the water heater.
2. Remove the jacket access panel(s) and insulation.
The thermostat protective cover should not be removed.
3. Press the red RESET button.
4. Replace the insulation and jacket access panel(s)
before turning on the power to the water heater.
Safety Controls