Remove all tape and packaging. Make sure the burners are properly seated and level.
Take the accessory pack out of the oven.
Check to be sure that no range parts have come loose during shipping.
LOCATION GUIDELINES
Do not locate the range where it may be subject to strong drafts. Any openings in the floor or wall
behind the range should be sealed. Make sure the openings around the base of the range that
supply fresh air for combustion and ventilation are not obstructed by carpeting or woodwork.
Your range, like many other household items,
is heavy and can settle into soft floor coverings
such as cushioned vinyl or carpeting. Use care
when moving the range on this type of flooring.
It is recommended that the following simple and
inexpensive instructions be followed to protect
your floor.
The range should be installed on a sheet of
plywood (or similar material). When the floor
covering ends at the front of the range, the area
that the range will rest on should be built up
with plywood to the same level or higher than
the floor covering.
This will allow the range to be moved for cleaning
or servicing. Also, make sure your floor covering
will withstand 180°F. (See the Installation Safety
Instructions section.)
Make sure the wall coverings around your range
can withstand the heat generated (up to 200°F)
by the range. (See the Installation Safety Instructions
section.)
TOOLS YOU WILL NEED
Phillips and flat-blade screwdrivers
Pencil and ruler
Two pipe wrenches (one for backup)
Open-end or adjustable wrench
Nut driver or wrench: 1/4
Drill
ADDITIONAL MATERIALS YOU MAY NEED:
Gas line shut-off valve
Pipe joint sealant or UL-approved pipe thread tape with
Teflon* that resists action of natural and LP gases.
*Teflon: Registered trademark of DuPont
Flexible metal appliance connector (1/2 I.D.). A 5-foot
length is recommended for ease of installation but other
lengths are acceptable. Never use an old connector when
installing a new range.
Flare union adapter for connection to gas supply line
(3/4 or 1/2 NPT x 1/2 I.D.)
Flare union adapter for connection to pressure regulator
on range (1/2 NPT x 1/2 I.D.)
Liquid leak detector or soapy water.
Lag bolt or 1/2 O.D. Sleeve anchor (for concrete
floors only).
Squeeze Connector matching the size of the bracket
opening (on the range back behind the wiring cover) and the
house conduit. Obtain only if replacing the power cord with
conduit.