For SPORTSMAN 450 H.O.. Also, The document are for others Polaris models: SPORTSMAN 570, SPORTSMAN 570 EPS, SPORTSMAN 570 EFI, SPORTSMAN 570 SP, SPORTSMAN 570 HD, SPORTSMAN 570 UTILITY EDITION, SPORTSMAN 570 SP HUNTER EDITION, SPORTSMAN 450 HO, SPORTSMAN 450 HO EPS, SPORTSMAN 450 HD, SPORTSMAN 450 UTILITY EDITION, SPORTSMAN TOURING 570, SPORTSMAN TOURING 570 EPS, SPORTSMAN TOURING 570 SP, SPORTSMAN X2 570 EPS, UTE 570 HD, SPORTSMAN 6X6 570

Loading ...
Loading ...
Loading ...
DIAGNOSTIC CODES
COMPONENT CONDITION SPN FMI
EPS MODELS ONLY
Steering Torque
Partial Failure
Condition Exists
520223 31
Steering Torque Full
Failure
Condition Exists
520224 31
EPAS Inverter
Temperature
Data Valid But Above
Normal Operational
Range - Most Severe
Level
520225 0
Data Valid But Above
Normal Operating
Range - Moderately
Severe Level
520225 16
EPAS
Communications
Receive Data Error
Data Erratic,
Intermittent Or
Incorrect
520226 2
Condition Exists
520226 31
Position Encoder
Error
Root Cause Not
Known
520228 11
Bad Intelligent Device
Or Component
520228 12
Condition Exists
520228 31
EPAS Software Error Bad Intelligent Device
Or Component
520229 12
Condition Exists
520229 31
EPAS Power Save
Condition
Condition Exists
520231 31
EPS SEPIC Voltage
Error
Voltage Above
Normal, Or Shorted To
High Source
524086 3
Voltage Below
Normal, Or Shorted To
Low Source
524086 4
68