en General information
20
KGeneral information
Gener al informat i on
The surfaces of the appliance are easily damaged.
Avoid damaging them during installation.
Exhaust duct
Note: The appliance manufacturer does not assume
any warranty for complaints attributable to the pipe
section.
The appliance achieves its optimum performance by
means of a short, straight exhaust air pipe and as
large a pipe diameter as possible.
As a result of long rough exhaust air pipes, many
pipe bends or pipe diameters that are smaller than
150 mm, the optimum extraction performance is not
achieved and fan noise is increased.
The pipes or hoses for laying the exhaust air line
must consist of non-combustible material.
Risk of damage from returning condensate. Install the
exhaust duct in such a way that it falls away from the
appliance slightly (1° slope).
Round pipes
An inner diameter of 150 mm is recommended.
Flat ducts
The inner cross-section must correspond to the
diameter of the round pipes.
dia. 150 mm ca. 177 cm
2
Flat ducts should have no sharp bends.
Use sealing strips for different pipe diameters.
Electrical connection
:Warning – Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
The mains plug of the mains power cable must be
easily accessible after installation of the appliance. If
this is not possible, an all-pole isolating switch must be
integrated into the permanent electrical installation
according to the conditions of overvoltage category III
and according to the installation regulations.
The permanent electrical installation must only be wired
by a professional electrician. We recommend installing
a residual-current circuit breaker (RCCB) in the
appliance's power supply circuit.
:Warning – Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do
not kink or pinch the connecting cable during
installation.
The required connection information can be found on
the rating plate inside the appliance; to access it, you
will need to remove the activated charcoal filter.
Length of the cable: approx. 1.30 m
This appliance complies with the EC interference
suppression regulations.
The appliance must be disconnected from the power
supply whenever installation work is being carried out.