Routine Maintenance
Winter Storage
If you planto storethe airconditionerduring the winter, removeit carefully from
the window accordingtothe installationinstructions.Coverit with plasticor
returnit to the originalcarton. NOTE: To prevent rust or electrical
connections from being damaged, store air conditioner in an upright
position and a dry place. A winter covercan bepurchasedfrom yourdealer.
The coverwill protectthe airconditionerwhen it isleft inplacethrough the
winter.
Before performing any service, unplug the power cord
from the electrical outlet.
After servicing,reversethe following procedures to reinstallthe air
conditioner.
Cleaning the Cabinet Front
Removethe front panel. Washwith warm, sudsywater. Rinseand drywith a soft
cloth. Neverusesolvents,cleaningfluids,abrasivecleanersor strongdetergents.If
the packagingleavesa gum residue,removewith a clothdippedin rubbing
alcohol.
Repairing Paint Damage
Inspectweather-exposedparts (cabinetshell,mounting hardware, ifused,etc.)
onceor twice a year, especially in areasnearoceansor where rustisa problem. If
needed,touch up with a good gradeof exterior paint.
Cleaning Inside the Air Conditioner
No Liquid shouldget into the motor, electrical control box, or
compressor electrical terminals.
1. Remove front panel.
2. With help and usingthe proper lifting methods to avoid personal injury,
remove the chassisfrom cabinet shell.* When removing the air
conditioner from cabinet shell or window, there may be water insidethe
basethat may spill on the floor. Becareful to avoid cutsfrom sharpmetal
-finson the front and rear coils.
3. Liquids should not get into electrical parts. Wrap the fan motor, electrical
control box, and electricalterminals in plastic.This will keep water or
other liquid from getting insidewhere it could damage the insulationand
cause serious trouble.
4. Clean and hose out base, coils, and water pans. Clean at least once a year
or more often if the coils and pans collect dirt, sand, leaves, algae, or
insects.
5. After cleaning, remove plastic protection. Wait 24 hours before starting
the unit again. This allows time for all areas to dry out.
NOTE: Water from rainfall or from normal use does not harm these
components since the water is not asforcefully driven into parts as a
stream of water from a garden hose.
*HANDLE NOTE: If the air conditioner hasa chassis handle, it is NOT intended for
lifting the unit. It isfor sliding the chassis WITHIN the cabinet shell only (to aid in
cleaning, maintenance, etc.).