Using the Air Conditioner To reduce the risk of fire, electric shock,or injuryto persons,read the
IMPORTANT SAFETYINSTRUCTIONSbefore operating this appliance.
NOTE: If the air conditioner isturned off,
wait 3 minutes before restarting. This
allows pressure inside the compressor to
equalize. Failure to follow these
instructions may cause inefficient
operation.
To begin operating the air conditioner, follow these steps:
I. Plug in the air conditioner. (To prevent electrical hazards, do not use an
extension cord or an adapter plug.)
2. Setthe exhaust vent to the CLOSED position.
3. Setthe TEMP Control to the coolest setting.
4. Setthe fan control at the highest level.
5. Adjust the louvers for comfortable air flow.
6. Once the room has cooled, select the POWERSAVERMODE andlor adjust the
TEMP Control to the setting you find most comfortable.
Review the "Air Conditioner Features" section for other settings.
Air Conditioner Features
VENT
OPEN CLOSE
MODE
OFF
HIGH _ FAN
T
MED \\ ' //POWER
COOL _ SAVER
LOW
COOL
TEMP
5
1 9
COOLER
(some models)
COOL
HIGH
LOW
HEATControl (some models)
The controls featured in this manual are representational of the many models
available. Your model may look slightly different.
TEMP Control
The TEMP Control servesas the thermostat to set the degree of room
coolness. Turn the knob clockwise from 1 to 9 to increase the cooling
temperature.
COOL MODES
When in one of the COOL settings, the air conditioner runs all the time,
circulating the air. Cooling starts only if the room temperature rises above the
coolness level selected on the TEMP Control, and stops once the set coolness
level is reached. This setting gives the most even room temperatures.
POWER SAVER MODE (some models)
The POWERSAVERMODE can save energy. In this setting, the fan will not run
unless the TEMP Control isset colder than the room temperature. When the
TEMP Control is set colder than room temperature, the air conditioner will
begin to circulate the air in the room. Cooling will begin in about 3 minutes.
The air conditioner turns off automaticalJy when the room reaches the level of
coolness selected. HIGH COOL is for fast cooling, MED. COOL isfor normal
cooling, and LOW COOL isfor quiet cooling.
HEAT (some models)
The HEAT selection provides quiet, efficient circulation of warm air. Turn the
selector to the HEAT setting and set the thermostat to the warmest setting.
When the HEATsetting isselected, the thermostat maintains the temperature by
automatically turning the heater on and off in response to room tempera-
ture. Once the room is warm, adjust the thermostat to a cooler setting. The
fan runs continuously to circulate air in the room.
MODE
OFF
HIGH FAN
COOco01._ONLY
MED POWER
SAVER
COOL
VENT
CLOSED
TEMP
5
1 9
COOLER
EXHAUST
HEAVYDU_
Side Air Model Control Panel